Enthalpy
Enthalpy h = u + pv is the energy carried by a flowing fluid. Learn why it's used for open systems, sensible and latent heat, c_p Δt calculations, steam enthalpies and heating curves.
When fluid flows into a device, it brings its internal energy plus the 'flow work' pv needed to push it in. Adding them gives enthalpy, which is why every steady-flow calculation — boilers, turbines, air heaters — is written in terms of h.
Enthalpy also captures latent heat: boiling water absorbs 2257 kJ/kg at 100 °C with no temperature rise.
An analogy
Enthalpy is like a delivery charge: the fluid's own energy (u) plus the cost of pushing it through the door (pv).
Sensible vs latent heat
Sensible heat changes temperature (Q = mcΔT). Latent heat changes phase at constant temperature: melting ice needs 334 kJ/kg, boiling water 2257 kJ/kg at 1 atm — over five times the energy to heat it from 0 to 100 °C.
Why enthalpy for open systems
In the steady-flow energy equation the flow work pv appears naturally with u, so engineers tabulate h. At constant pressure, heat added equals Δh — which is why c_p (not c_v) is used for flowing gases.
Reference states
Only differences in h matter. Steam tables set u = 0 for saturated liquid at 0.01 °C; refrigerant tables use other references (IIR: h = 200 kJ/kg at 0 °C liquid). Never mix values from tables with different references.
Enthalpy of reaction and psychrometrics
Combustion releases enthalpy of formation differences (heating values: LHV/HHV). Moist-air enthalpy (per kg dry air) combines air and vapour: h ≈ 1.005T + ω(2501 + 1.86T) — the basis of HVAC psychrometric charts.
Formulas
- Definition:
h = u + p·v - Ideal gas / liquid sensible heat:
Δh = c_p ΔT - Heater / boiler:
Q̇ = ṁ (h₂ − h₁) - Latent heat:
Q = m · h_fg
Worked example: Air heater duty
Given: ṁ = 1 kg/s air, 20 → 200 °C; c_p = 1.005 kJ/kg·K
Find: Heater power.
- Q̇ = 1 × 1.005 × 180 = 180.9 kW
Answer: ≈ 181 kW
Worked example: Boiler heat input
Given: Feedwater h₁ = 195 kJ/kg; Steam out 3 MPa 400 °C, h₂ = 3232 kJ/kg; ṁ = 10 kg/s
Find: Boiler heat rate.
- Q̇ = 10 × (3232 − 195) = 30 370 kW
Answer: ≈ 30.4 MW
Common mistakes
- Wrong: Forgetting latent heat when a phase change occurs. — Right: Check the phase at each state; add h_fg when boiling/condensing.
- Wrong: Using c_v for flowing gases. — Right: Use c_p for constant-pressure/flow processes.
Applications
- Boilers & HRSGs: Heat duty = ṁ Δh across economiser, evaporator and superheater sections.
- HVAC: Enthalpy of moist air drives cooling-coil capacity including dehumidification.
- Process heating: Steam is used for heating because condensing latent heat delivers huge energy at constant temperature.
Key takeaways
- h = u + pv — the energy of flowing fluid.
- Sensible: c_pΔT; latent: h_fg.
- Q̇ = ṁΔh for heaters, boilers, coolers.
- Only differences matter; keep one reference.
Going further
- Joule–Thomson effect: Throttling a real gas changes its temperature; below the inversion temperature it cools — the basis of gas liquefaction.
- Stagnation enthalpy: h₀ = h + V²/2 is conserved in adiabatic flow — key for high-speed flows and turbomachinery.
- Heating values: HHV includes condensing the water in combustion products; condensing boilers recover part of that difference.