Steel Structures

Structural steel is strong, ductile and fast to build. Learn steel grades and sections, limit-state design (IS 800 / EC3), tension and compression members, beams with plastic moment and lateral-torsional buckling, bolted and welded connections, and fire and corrosion protection.

Skyscrapers, long-span roofs, industrial buildings, transmission towers and many bridges are built in steel. It offers high strength-to-weight, predictable ductile behaviour and prefabrication off-site.

Steel design checks each member and connection for yielding, buckling and fracture, with deflection and vibration limits for serviceability.

An analogy

A steel frame is like a meccano kit: standard rolled pieces bolted or welded together — but each piece must be checked for stretching, squashing, bending and buckling.

Sections and grades

Hot-rolled I-beams (ISMB/IPE/W), channels, angles, hollow sections (SHS/RHS/CHS), and built-up plate girders. Common grades: E250/S275/A36 and E350/S355/A572. Cold-formed light-gauge sections are used for purlins and light framing.

Members

Tension members: gross-section yielding, net-section rupture at bolt holes and block shear. Compression members: flexural buckling governed by slenderness and imperfections (buckling curves). Beams: plastic moment for compact sections, reduced by lateral-torsional buckling if the compression flange isn't restrained; web shear and bearing checks.

Connections

Bolted (bearing or slip-critical/friction grip with HSFG bolts) and welded (fillet, butt). Simple (pinned) connections transfer shear; moment connections transfer bending. Connection design often governs cost and erection speed.

Stability, fire and fatigue

Frames need bracing or moment connections for lateral stability; second-order effects matter for sway frames. Steel loses ~50 % strength near 550 °C — protected by intumescent paint, boards or concrete encasement. Bridges and crane girders are checked for fatigue at welded details. Corrosion protection by galvanising or paint systems.

Formulas

Worked example: Laterally restrained beam

Given: I-section with Z_p = 650 × 10³ mm³; E250, γ_m0 = 1.10, β_b = 1

Find: Design moment capacity.

Answer: ≈ 148 kN·m

Worked example: Bolt shear capacity

Given: M20 grade 4.6 bolt (f_u = 400 MPa); A_nb = 245 mm², single shear, threads in plane

Find: Design shear capacity.

Answer: ≈ 45 kN per shear plane